CLM-36 Capacitive level meters


For continuous level measurement of liquid and bulk-solid materials

  • Direct mounting into containers, silos, vessels, basins, reservoirs, etc
  • Easy and quick connecting by connector
  • Continuous adjustment of initial capacity
  • Variants for usage in explosive areas, high temperature performance
  • Current (4 ... 20 mA) or voltage (0 ... 10 V) output

Capacitive level meters CLM® are designed for continuous level measurement of liquids, powders and bulk-solid materials in vessels, tanks, sumps, containers, silos, etc. CLM consists of the stainless steel housing with electronic module and the measuring electrode. Type of measuring electrode is defined by kind of use and type of measured media.

Sensitivity (SPAN) and initial capacity compensation (ZERO) can be fluently set. CLMs are offered in version (N) for non-hazardous environments or (Xi) version to explosive areas up to zone 0 or zone 20, high temperature performance and several types of process coupling are also available.

Description

Features of variants

  • CLM–36_–10 With uncoated rod electrode for level measurement of non-conductive liquids (oils, diesel, petrol) and powder or bulk-solid materials (flour, sand, cement, plastic granulates, etc.). Max. length 5m.
  • CLM–36_–11 With fully (PFA) coated rod electrode for level measurement of water and conductive liquids incl. wasted liquids in metallic vessels, concrete sumps, reservoirs, etc., better behaviour against aggressive media, lower adhesion to some complicated media, chemical resistance. Max. length 3m
  • CLM–36_–12 With fully (FEP) coated rod electrode for level measurement of water and conductive liquids incl. wasted liquids in metallic vessels, concrete sumps, reservoirs, etc., better behaviour against aggressive media, lower adhesion to some complicated media, chemical resistance. Max. length 3m.
  • CLM–36_–20 With uncoated rod electrode and reference tube for accurate level measurement of clean nonconductive liquids (oils, diesel, petrol). By means of reference tube the output signal does not depend on the dimensions and shapes of a vessel. Max. length 3m.
  • CLM–36_–22 With fully FEP coated rod electrode and reference tube for accurate level measurement of conductive liquids. Main use is for measurement in plastic vessels or tanks. Impossible to use for waste and high viscosity liquids and bulk-solid materials. Max. length 3m.
  • CLM–36_–30 With uncoated stainless steel rope electrode and uncoated weight for level measurement of bulk-solid materials (grains, sand, flour, cement, etc.). Max. length 20m.
  • CLM–36_–31 With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos. Max. length 20m.
  • CLM–36_–32 With fully coated rope electrode and coated weight (rope insulation FEP, weight insulation PTFE), for level measurement of electrically conductive and non-conductive liquids. Max. length 20m.
  • CLM–36_–40 With two coated electrodes (rode insulation FEP, head fully PTFE), for level measurement of aggressive liquids. Performance for non-explosive areas only. Max. length 2m.
CONTINU LEVEL METER CLM-36

10

12 20 22  30 en 31 40
LANDBOUW, VOEDSEL VERWERKING, VERPAKKINGSTECHNIEK          
Maïs , granen, zaden √√ √√
Mout en diervoeding - Droge √√ √√
Mout en diervoeding - Nat
Chocolade , fruit jam √√
Dranken - Water , Siroop , wijn , melk √√
Spiritualiën √√
Suiker , zout √√ √√
Poeders , meel, koffie √√
plantaardige oliën √√ √√ √√
WATERBEHANDELING MILIEU            
Water opslagtanks √√ √√ √√
Rioolwater pompputten √√
Open kanalen
Putten , bronnen
Droogloopbeveiliging pomp
Reservoirs , Rivieren
Water lekdetectie
CHEMISCHE INDUSTRIE            
Alkalische vloeistoffen , chemicaliën , reagentia
Bulkgoederen, Zout , Meststoffen √√
Vloeibare wasmiddelen
Anorganische oplosmiddelen, zuren √√
Harsen √√
Lekdetectie agressieve vloeistoffen 
PHARMACIE            
Niet-geleidend vloeistoffen, organische oplosmiddelen √√ √√
Schoon water , De-mi water, RO-water √√ √√
Pasta's √√
PETROCHEMISCHE INDUSTRIE            
Olie , Diesel √√ √√ √√
Benzine √√ √√ √√
Lekdetectie
TRANSPORTMIDDELEN, MOTOREN            
Diesel tanks √√ √√
Koelvloeistoffen in motor √√ √√
Oliën in motoren, Compressoren
VERWARMING, HVAC            
Watercondensaat tanks , koelers √√
Ketels , Stoom generatoren
Houten pellets , chips
Stookolie √√ √√
BOUWEN EN PROCESINDUSTRIE            
Cement, kalk poeder, Krijt √√
Grind
Vloeibare asfalt, bitumen
Zand
MACHINES            
Hydraulische olie √√ √√
Smeermiddelen √√
Koelemulsie √√ √√
PLASTIC INDUSTRIE            
Korrels √√ √√
Poeders √√ √√

Specifications

principe
House
meetelement
Process Connection
uitgang
Nominal diameter
Brand Georg Fischer
materiaal
Manometer diameter
glycerine
Hygienic
Ask a quotation for this product

© 2012-2018 Ebora Process Automation is a trademark of Ebora BV - 't Veld 3 - S, Heteren, Netherlands - info@ebora.nl