Design
EN 837-1
Nominal size in mm
160
Accuracy class
0.6
Scale ranges
0 ... 0.6 to 0 ... 1,600 bar
or all other equivalent vacuum or combined pressure and vacuum ranges
Adjustment medium
≤ 25 bar: Gas
> 25 bar: Liquid
Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value
Permissible temperature
Ambient:
-40 ... +60 °C without liquid filling
-20 ... +60 °C gauges with glycerine filling (Model 333.50)
Medium:
+200 °C maximum without liquid filling
+100 °C maximum with liquid filling (Model 333.50)
Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C):
max. ±0.4 %/10 K of full scale value
Ingress protection
IP65 per IEC/EN 60529
principe | Manometer |
---|---|
Process Connection | thread G ", thread NPT |
Nominal diameter | |
House | Stainless steel |
meetelement | Roestvaststaal |
uitgang | Visueel |
Scale range | |
Manometer diameter | 160 mm |
aansluitpositie | onder (6 uur) |
glycerine | glycerine |
Brand | Wika |
Hygienic | Hygienic |